Wednesday, November 18, 2015

Algeria National Lab Ordered Whole Lighting Test Systems from Lisun Group

This Algeria client built a new big lab not long ago. They ordered all the test instruments from Lisun Group. Lisun sent two engineers to help them for the installation and training. Here are some photos to share with you.

Group photo with our clients:






LPCE-1 LMS-5000 spectrophotometer and integrating sphere system:




Waterproof test system:


Waterproof test system for IPX1 and IPX2:






Waterproof test system for IPX3 and IPX4:




Waterproof test system for IPX5 and IPX6:


Waterproof test system for IPX7:


Glow wire tester:




Horizontal and Vertical Flame tester:


High and low temperature humidity chamber:




Dustproof test:




Aging and life test rack:






IK level tester for IK07 to IK10:


Spring impact hammer IK level tester for IK01 to IK06:


The installation and training lasted for more than ten days. And it is very successful experience for Lisun and for our client. This client is planning to order more test systems from Lisun.

Standard operating procedures of Spectroradiometer & Integrating Sphere System



Spectroradiometer & Integrating Sphere System as main test device to measuring LED lamps, it’s as a most important device to judge the quality of lighting products. How to operating these device and make it have better work condition became the point, so the standard operating procedures of device is necessary. In the practice, the standard operating procedures have two parts: one is standard laboratory hardware requirement; the second is operator’s skills and practices experience.
The following is details introduction:
The first part laboratory hardware environment, normally, there have some requirements about photometric lab: Lab room size, this will be depend on by test device’s dimension and height of test device; the second is inside air flow at lab room, temperature range, humidity range and safety protection measures. These are general requirements, the details specs and requirement can refer relevant ISO and IEC etc standards.
 
The second part is point. First we need know what’s kind of device of spectroradiometer & integrating sphere system have: a one full test system consist of spectroradiometer, optical fiber, digital power meter(measuring electrical parameters), AC power source(power supply the tested lamp), DC power source(power supply the standard lamp), integrating sphere(provide the test environment), standard lamp(calibrate the integrating sphere) and cabinet(load all device together).
Before test, there must do following things:
1、 Check all connections to make sure all the connecting is correct(the connection included between the device and device and between device and power supply);
2、 Open the computer and software, then set up relevant parameters(like the calibration data);
3、 Install the standard lamp at right place of integrating sphere, please refer this procedure according to lab requirements;
4、 Turn on the DC power source after successful install the standard lamp, input the calibration data of standard lamp to test software, then start pre-heat the standard lamp and calibrating. After successful calibration, turn off the DC power source and take uninstall the standard lamp, then switch the DC to AC power supply;
5、 Install the tested lamp(attention the type of lamp, if the tested lamp is emitting light in all directions, like the LED bulb, CFL etc which had better install it at centre position of integrating sphere to do 4π test; if tested lamp is emitting light in forward direction, like the LED street lamp, LED panel etc which had better install in at side position of integrating sphere to do 2π test. After installed the tested lamp, turn on the AC power source and set pre-hear time at software, normally the pre-heat time need 10 minutes will be ok;
6、 After pre-heating, the software will automatic analysis the data and get results, then print out the test report;
7、 After finished the above all procedures, then turn of the power supply of device and switchboard power supply;

LPCE-2(LMS-9000) led wavelength meter integrating sphere LED Test System for Lumen flux cct measurement

LPCE-2(LMS-9000) led wavelength meter integrating sphere LED Test System for Lumen flux cct measurement


Introduction:

LPCE-2(LMS-9000) Integrating Sphere Spectrophotometer System is high precision CCD Spectroradiometer & Integrating Sphere Test System, it is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.

System Configuration: 
High Precision CCD Spectroradiometer (LMS-9000A or LMS-9000B), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC3005), AC Power Source (LSP-500VA), Integrating Sphere (IS-1.5M55P and IS-0.3M), Standard Light Source (SLS-50W and SLS-20W), Optical Path Converter (LS512B), 19 Inch Cabinet (CASE-19IN)


Measures:
 Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth,Dominant Wavelength, Color Purity, CRI, Spectrum Test
 Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux
 Electrical: Voltage, Current, Power, Power Factor

Specification:
 Spectral Range Wavelength: 380nm ~780nm (Option: 380nm ~ 1050nm or 200nm ~ 780nm)
 Accuracy of wavelength: ±0.5nm
 Photometric linear: ±0.5%
 Time of integration: 0.1mS~20S 
 Stray light: <0.015%(600nm) and <0.03%(435nm)
 Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard illuminant A )
 Range of related color temperature measurement: 1000~100000k
 Accuracy of related color temperature: ±0.3% (under standard illuminant A )
 Tolerance of color rendering index: ±(0.3%±0.3)
 Connect with PC via USB, English version software can be run under WinXP and Win7

LISUN Customers who have bought LPCE-2 Spectrophotometer Integrating Sphere System:
LPCE-2(LMS-9000A) High Precision Spectroradiometer Integrating Sphere System Online Video:   http://www.lisungroup.com/product-id-340.html

Company Information

Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Hong Kong and Shanghai. The Lisun Group were award CE certificate. As a CIE Supportive Member, all of the test instruments of Lisun Group are designed according to CIE Standards. Lisun Group's products have been sold to more than 50 countries and regions in Europe, America, Australis, Africa,South America and Asia. Its quality is well accepted by many companies such as GE, Phillps, Sharp, OSRAM, SONY and so on.

Lisun Group Certificates:


Lisun Group Hong Kong Lighting Fair:
 


Install and Training Customers:
Our Services

IES file test Service:
we will test two lamps for you for free and supply you the following two kinds of test report.

1.    LM-79 IES or LDT files report for distribution curve intensity test by Goniophotometer System
2.    LM-79 report for lumen, CCT, CRI, Spectrum test by Integrating Sphere & Spectroradiometer System LPCE-2(LMS-9000)

LSG-2000 LED Luminous Intensity Mirror Goniophotometer Testing System Meets IES CIE121-1996

LSG-2000 LED Luminous Intensity Mirror Goniophotometer Testing System Meets IES CIE121-1996


LSG-2000 Goniophotometer with Rotating Mirror (Moving Mirror Goniophotometer) completely meet LM-79 Clause 9.3.1. The LSG-2000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.

 Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Lsocandela Diagrams, Efficient Luminescence Angle Etc.
Features:
•Many national patents pending on hardware and software.
•CIE Class A & Constant temperature photo detector (Class L detector can be optional).
•High degree of intelligent and test function is complete.
•The rotation motor is from Japan MITSUBISHI MOTORS and  it uses Germanic Angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop.
•The working principles are according to IESNA and CIE. This instrument is specially recommended by LM-75, LM-79 and CIE121-1996.
•With some optional instruments, it has good expanding functions
•The position and working state remain the same as it is under working.
•Special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries.
Specifications:
•The tested luminaire rotates around the mirror with an angle of (γ)±180°(or 0-360°) and the tested luminaire rotates around itself with an angle of (C)±180°(or 0-360°).
•The accuracy of angle: 0.1° Resolution of angle: 0.01°
•Accuracy of photometry: CIE class A (Standard Class) or Class L.
•The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux.
• RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7
 
LSG-2000 can be used with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system "Goniospectroradiometer (LSG-2000CCD)". 


LSG-2000 Goniophotometer with Rotating Mirror (Moving Mirror Goniophotometer) online video:  http://www.lisungroup.com/product-id-211.html


LISUN LSG Series Goniophotometer:

Company Information
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Hong Kong and Shanghai. The Lisun Group were award CE certificate. As a CIE Supportive Member, all of the test instruments of Lisun Group are designed according to CIE Standards. Lisun Group's products have been sold to more than 50 countries and regions in Europe, America, Australis, Africa,South America and Asia. Its quality is well accepted by many companies such as GE, Phillps, Sharp, OSRAM, SONY and so on.

Our Services

IES file test Service:
we will test two lamps for you for free and supply you the following two kinds of test report.

1.    LM-79 IES or LDT files report for distribution curve intensity test by Goniophotometer System
2.    LM-79 report for lumen, CCT, CRI, Spectrum test by Integrating Sphere & Spectroradiometer System LPCE-2(LMS-9000)

Lisun Electronics (Shanghai) Co., Ltd.

Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Hong Kong and Shanghai. In 2012, we built a high level products show room & lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and develop the world high-technology CFL & LED Test Instruments. Its quality system has been strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the third party lab and were awarded by CE certificate. As a CIE Supportive Membership, all of the test instruments produced by Lisun Group were designed according to CIE Standards.
Lisun Group’s products have been sold to more than 50 countries and regions in Europe, America, Australia, Africa and Asia. Its quality was well accepted by many of world-famous companies such as GE, Philips, Sharp, OSRAM, SONY and so on. Lisun Group wins thousands of customers’ trust with motto “Right Product, Right Price and Right Service”. We will continue presenting more and more high quality products to our customers in future.

Email:
Website:
Tel:
+86-021-51083341
Address:

113-114, No.1 Building, Nanxiang Zhidi Industry Park, No.1101, Huyi Road, Jiading District, Shanghai, China